Situation • Permeability of the sinter mix on the strand unknown • Water dosing in the granulation suboptimal • Inhomogeneous burn-trough • Losses of productivity and quality Solution • Injection of air trough permeability probes • Measurement of permeability on the strand by the pressure loss • Analysis and optimisation of granulation and water dosing • Control of burn-through and strand speed
Benefits • Sinter process more steady • Raised sinter quality • Increase of permeability and production • Reliable permanent operation • Release of staff
|